DC Power Supply
Linear Regulated
Series: BVA
- Single, dual, tripple outputs
- Worldwide field selectable 100/117/220/230-240VAC or 208/240/440/460/480VAC Input
- Rated full load at 50°C
- Overload and short circuit protection
- Remote Sense
- Reverse polarity protection
- Open sense lead protection
- Overvoltage Protection (OVP) on 5V main outputs
- 2 year warranty
Agency Approval
- UL 1950, Third Edition, File #E181899
- CSA C22.2 No. 950, UL File #E181899
- CB Scheme, File #MC3535
- CE Marked
Specifications
- AC Input: Field selectable taps for 100/117/220/230-240VAC or 208/240/440/460/480VAC ±10%, 50/60 Hz
- DC Output: Output is floating; either positive or negetive terminal can be grounded
- Line Regulation: ±0.05% for 10% line change
- Load Regulation: ±0.05% for 50% load change
- Thermal Regulation: ±0.02% per °C maximum, ±0.005% per °C typical
- Output Ripple: 2mV RMS maximum, 3mV P-P
- Dynamic Response: 30 microseconds for 50% load change
- Stability: ±0.3% for 24 hour period after 1 hour warm-up
- Short Circuit and Overload Protection: Foldback current limiting, set at 120% of nominal
- Overvoltage Protection: All 5VDC main outputs and is factory set at 6.2V±0.4V(fixed)
- Remote Sensing: Standard on all outputs above 30 watts
- Efficiency: 5V units: 45%; 12 and 15V units: 55%; 24V and higher units: 60%
- Operating Temprature: 0°C to 50°C full rated load, derate linearly to 40% at 70°C
- Storage Temprature: -55°C to +85°C
- Vibration: Per MIL-STD-810B, Method 514, Procedure I, Curve AB (to 50 Hz)
- Shock: Per MIL-STD-810B, Method 514, Procedure V
- Finish: Clear aluminium chassis. Also serves as heat sink
- Mounting: Units can be mounted on several surfaces
Results:
102
Standard Parts:
Results: 102
Compare | Part No. | Input | Number of Outputs | Output 1 | Output 2 | Output 3 | UL File No. | RoHs | Reach | Datasheet | Quanitity Available | Check Price |
---|---|---|---|---|---|---|---|---|---|---|---|---|
BVA-48ES4-480 | 240/480V | Single Output | 48V @ 4A | - | -- | E181899 | Yes | Yes | View | 1 | Check Price | |
BVA-48FS8-480 | 240/480V | Single Output | 48V @ 8A | - | -- | E181899 | Yes | Yes | View | 0 | Check Price |